SPT Formulas
Note
60 is used in this case to represent 60% hammer
efficiency and can be any percentage of hammer efficiency
e.g. \(N_{55}\) for 55% hammer efficiency.
Description of symbols used in SPT Corrections
| Symbol | Description |
|---|---|
| \(N_R\) | Recorded SPT blow count |
| \(C_H\) | Hammer efficiency correction factor |
| \(C_B\) | Borehole correction factor |
| \(C_S\) | Sampler correction factor |
| \(C_R\) | Rod length correction factor |
| \((N_1)_{60}\) | SPT blow count corrected for overburden pressure |
| \((N_1)_{60 \, (CORR)}\) | SPT blow count corrected for dilatancy |
| \(N_{60}\) | SPT blow count corrected for 60% hammer efficiency |
| \(C_N\) | Overburden pressure correction factor |
| \(\sigma_o\) | Effective overburden pressure at the test depth |